FOB Price:
US 1,000-100,000 / Set
Min.Order Quantity:
1 Set/Sets
Supply Ability:
200 Set/Sets per Month
Port:
shanghai
Place of Origin:
Jiangsu, China (Mainland)
Payment Terms:
T/T
Brand:
LNEYA
Products Model:
SUNDI-435W-2TN
Share:
  • Products Details
  • Company Profile

Quick Details

  • Brand Name: LNEYA

    Model Number: SUNDI-435W-2TN

    Place of Origin: Jiangsu, China (Mainland)

Packaging & Delivery

  • Packaging Details: export wooden case
  • Delivery Detail: 20-30 working days

Specifications

Dynamic Temperature Control systems

 

Cooling And Heating Temperature Control systems

SUNDI -40℃ ~ 200℃ Parameter

 

 

 

Product Description

Typical Applications

Reactor Systems Autoclaves
Pilot Systems
Mini Plant Systems
Scale up for Operational Development
Double wall reactors
Advanced-Flow Reactors
Distillation Systems
Material Testing
Combinational Chemistry
Semiconductor Industry
Vacuum Chambers

Advantages & Functions

Working temperatures from -100℃ to +350℃
Previously unachievable performa

Intelligent temperature control
Maximum process stability and reproducibility
Adop plate heat exchager,Pipeline heating,

the fastest heating and cooling rates.
High cooling power

Large temperature range without fluid change
Closed system,extend thermal fluid lifetime
Incredibly compact
7-inch,10-inch color TFT touch screen display
Comprehensive warning and safety functions
Rapid cooling down from high temperature

Use magnetic drive pump,solve the circulation pump leakage

Structure design

 

 

A fully closed piping design, high efficiency plate heat exchanger used to reduce the

demand for the thermal fluid utilization while providing the system to achieve the rapid

ups and downs in temperature The whole system is a closed liquid circulation system

with the expansion of container, expansion of the container and the liquid circulation is

adiabatic, and do not participate in liquid circulation, only mechanical connection,

no matter the temperature is a high temperature or low temperature, the tank

temperature is limited to 60℃. Therefore, during the process the risk of imbibing

and volatilization of the heat conducting medium is reduced. There following

advantages

for the user.

 Only the heat conduction medium in the expansion container touches the oxygen

 in the air. (The container temperature is limited to 60℃).

 No volatilization of the heat conducting medium at high temperature.

 No need to change the heat conducting medium. Continuous control of the temperature 

 of the below range can be done without rising the pressure: -80℃~190℃, -70℃~220℃,

 -88℃~170℃, -55℃~250℃, -30℃~300℃.

Display funcation

 The Refrigeration system displays various information on the touch screen.

1. Displays all the kind of process control temperatures.

2. Shows the liquid level of the heat conducting medium in the expansion vessel.

3. Shows indication for refrigeration system working.

4. Shows indication for heater working.

5. Shows indication for circulation pump working.

6. Displays the temperature control (materials temperature control pattern, heat

conducting medium temperature control ).

7. The temperature upper limit, lower limit control can be set.

8. The temperature difference between jacket & reactor material can be set.

9. Shows the alarm to add the liquid when it is empty.

10. The refrigeration compressor can be set to operate manually or automatically.

11. Simple Menu to use. 

    

Process Control Schematic diagram

Change the control settings of the method, the response as soon as possible in the 

process of the system lags behind, be the smallest system overshoot. Controlled by 

two PID (PID is a variable in each group) control loop structure, known as the two 

sets of control loops: the main circuit and from the circuit, the main control loop from 

the loop output as the settings. 

System with feedforward with PV, the master PID loop operation results of the PV 

output and feedforward signals as the composite of the settings from the control loop, 

through such control of the temperature gradient to ensure the accuracy of temperature 

control system.

High repetative of tempeature control effect 

Each cycle curve slope is consistent and greatly improve the consistency of production thermostatically control environment.

 

Circulation Pump

High temperature resistant low temperature magnetic drive pump or a leak-free high

and low temperature shield-driven pump, reduce the risk of system leakage. At the

same time the system has the advantages of low noise and big traffic flow.

 

 

Connecting Pipe

 

LNEYA Dynamic Temperature Control systems in practice

In comparison to other thermal control systems, Dynamic Temperature Control systems

differ sometimes considerably in their thermodynamic characteristics. In practice Dynamic Temperature Control systems offer definite advantages in your work: noticeably shorther heating and cooling times, better stability and reproducibility through the entire process

chain, greater safety for expensive glass reactors and the contained substances, together

with simple and easy operation.

 

Heat Conduction Medium

It is important to choose the suitable heat conduction medium, to make sure that

system works stably.To choose the suitable medium according to the working

temperature of the system is essential.

The package kinds of LNEYA heat conduction medium are 10L, 25L, 30L, 200L.

when ordering the heat conduction medium, the heat conduction medium for constant

temp       control system, channel, and external circulation equipments.

 

Technical Parameters:

 

 

Model

SUNDI-425W-2TN

SUNDI-425-2TN

SUNDI-435W-2TN

SUNDI-435-2TN

SUNDI-455W-2TN

SUNDI-455-2TN

SUNDI-475W-2TN

SUNDI-475-2TN

SUNDI-4A10W-2TN

SUNDI-4A10-2TN

Temperature range ℃

-40℃~200℃

-40℃~200℃

-40℃~200℃

-40℃~200℃

-40℃~200℃

Controller mode

Feed forward PID + Our special dynamic control calculation, PLC controller

Temp. control

Option: process temperature control or jacket oil temperature control

Temp. difference

Set or control the temperature difference between jacket oil and raw material process

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium: PT100   Raw material process: PT100 or 4~20mA      

Temp. accuracy

±1℃

±1℃

±1℃

±1℃

±1℃

Heating power

2.5kW

3.5kW

5.5kW

7.5kW

10kW

Cooling

capacity

200℃

4kW

6kW

8kW

12kW

17kW

100℃

4kW

6kW

8kW

12kW

17kW

20℃

4kW

6kW

8kW

12kW

17kW

0℃

3kW

5kW

6kW

10kW

15kW

-20℃

2kW

3.2kW

4.2kW

6kW

8kW

-35℃

0.9kW

1.5kW

2kW

2.8kW

3.6kW

Circulation pump

Max25L/min

2BAR

Max35L/min

2.5BAR

Max35L/min

2.5BAR

Max50L/min

2.5BAR

Max50L/min

2.5BAR

Compressor

Tecumseh

Copeland

Copeland

Copeland

Copeland

Expansion valve

Danfoss

Danfoss

Danfoss

Danfoss

Danfoss

Oil separator

Emerson

Emerson

Emerson

Emerson

Emerson

Evaporator

KAORI Plate heat exchanger

Operation Panel

10-inch color touch screen controller, temperature curve record, data export to excel format.

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device,

liquid low level protection, high temperature protection and temperature fault protection.

Closed
circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,

pressure do not rise up when system is running. The system will supplement oil automatically at low temperature.

Refrigerant

R-404A

R-404A

R-404A

R-404A

R-404A

Connection size

DN-20 or

M24*1.5

DN20 or

M30*1.5

DN20 or

M30*1.5

DN20 or

M30*1.5

DN20 or

M30*1.5

Water-cooled type W

(cooling water at 20℃)

1200L/H

1.5bar~4bar

1400L/H

1.5bar~4bar

1700L/H

1.5bar~4bar

2100L/H

1.5bar~4bar

2500L/H

1.5bar~4bar

Dimension

water-cooled

400*600*1250

550*700*1350

550*700*1350

600*700*1550

650*700*1550

air-cooled

600*680*1350

750*750*1450

750*750*1650

1050*750*1300

1150*800*1350

Weight

water-cooled

220kg

295kg

350kg

400kg

450kg

air-cooled

255kg

330kg

390kg

435kg

495kg

Power

AC 380V 50HZ

7.6kW (max)

AC 380V 50HZ

10.5kW (max)

AC 380V 50HZ

16.5kW (max)

AC 380V 50HZ

23kW (max)

AC 380V 50HZ

29.5kW (max)

Case material

SUS 304

SUS 304

SUS 304

SUS 304

SUS 304

Optional

Optional Ethernet interface, configure PC operating software

Optional

Optional outside touch screen display controller (separated), the communication line distance is 10 meter.

Optional power

220V 60HZ three-phase, 440V~480V 60HZ three-phase

 

  

 

2015 Corning Reactor and its Ancillary Equipment Technology Exchange Meeting

 

 

 

 

 

 

 
  • Email to this supplier
  • To :
    Jack Yan  |  wuxi guanya refrigeration technology co.,ltd
  • *Subject :
  • Quantity Order:
  • *Message :

  • Your message must be between 20-2000 characters
  • + Add attachments :
    Select File  (Max 2 files) 
  •  Please enter your company name:

    Please make sure your company name is entered correctly.

  • * Please enter your email address:

    Please make sure your email address is entered correctly.

  • * Please enter your mobile phone:

    (+)   - 

    Please make sure your mobile phone is entered correctly.

Verified Supplier - wuxi guanya refrigeration technology co.,ltd Bussiness Type:  Manufacturer
Scale:  51 - 100 People
Country/Region:  China (Mainland)/Asia
Established:  2012